What wet bulb temperature is

Wrap a thermometer bulb in wet muslin and blow air across it. Water evaporates, evaporation takes heat, and the thermometer settles below the air temperature. Where it settles is the wet bulb temperature.

It is the coldest anything can get by evaporation alone in that air — a swamp cooler, a wet shirt, a sweating person. In dry air the gap is large: at 100°F and 15% humidity the wet bulb is around 68°F. In saturated air there is no gap at all, because no more water will evaporate.

That is why it matters more than the thermometer reading. The dry bulb tells you how hot the air is. The wet bulb tells you whether you can do anything about it.

Reading the answer

The number this calculator gives is the psychrometric wet bulb: shaded and ventilated. It is what people mean in conversation and in the climate literature, and it is not WBGT — that is a different, weighted quantity that includes sunshine. If you need the one that safety rules are written against, use the WBGT estimator.

Stull (2011) empirical wet-bulb regression equation

Equation (T in °C, RH in %)
Tw = T * atan[0.151977 * (RH + 8.313659)^(1/2)] + atan(T + RH) - atan(RH - 1.676331) + 0.00391838 * RH^(3/2) * atan(0.023101 * RH) - 4.686035
Default input
Air temperature T = 90°F (32.22°C), Relative humidity RH = 60% (Dew point = 74°F / 23.3°C)
78.8°F (26.0°C) Psychrometric wet bulb (Raised) — 16.2°F (9.0°C) below the 35°C (95°F) theoretical limit, with a heat index of 100°F. Source: Stull, R. (2011), Journal of Applied Meteorology and Climatology 50(11): 2267–2269 (atan arguments in radians, valid for −20°C to 50°C and 5% to 99% RH at 1013.25 hPa).
Psychrometric wet bulb temperature reference bands and physiological meaning (literature synthesis from Sherwood & Huber 2010 and Vecellio et al. 2022).
Wet bulb (°F / °C) Band Physiological meaning & precautions
< 75°F · < 24°C Well below the limit Sweat evaporates freely. Heat stress is a question of exertion and duration rather than physical limits.
75–81°F · 24–27°C Raised Evaporative cooling still works, but less efficiently. A normal summer figure in a humid climate; hydrate and pace heavy work.
82–87°F · 28–30.5°C High Sustained heavy work becomes difficult to perform safely because the body cannot shed metabolic heat as fast as work produces it.
88–94°F · 31–34.9°C Severe Approaching and exceeding experimental uncompensable heat stress limits (31°C) for resting adults. Prolonged outdoor exposure is dangerous even at rest in shade.
≥ 95°F · ≥ 35°C Theoretical survivability limit At 35°C (95°F) wet bulb, evaporation cannot cool skin below core body temperature. Shade and fans do not prevent overheating; air conditioning is required.

Worked example: the same day, two ways

Phoenix, dry heat
108°F, 15% humidity → wet bulb 74°F
Houston, humid heat
92°F, 75% humidity → wet bulb 84°F
10°F Houston's wet bulb is ten degrees higher despite being sixteen degrees cooler on the thermometer. Evaporative cooling has far less room to work there.

Which is why "but it's a dry heat" is not only a cliché. It is thermodynamics.

Where the 35°C limit comes from

In 2010 Sherwood and Huber published a limit based on a simple observation: human skin sits near 35°C while the body is shedding heat, so if the wet bulb temperature of the surrounding air reaches 35°C there is nowhere for that heat to go. Not shade, not a fan, not drinking water. Only cooler or drier air.

Two things are worth knowing about that number:

  • It is a theoretical ceiling, not a safety threshold. Later experimental work at Penn State found that critical environmental limits for young, healthy, resting adults sit closer to 31°C wet bulb, and lower again for older people or anyone doing work.
  • It is nearly unreached, but not entirely. Analyses of station data have found brief 35°C wet bulb events along the Persian Gulf and in parts of Pakistan, lasting hours rather than days.

So a wet bulb of 31°C is not "comfortably below the limit". It is already at the edge of what published human trials describe as survivable for a resting adult.

What this calculator assumes

  1. Standard sea-level pressure (1013.25 hPa). At altitude the true wet bulb is slightly lower.
  2. Stull's fitted range: −20°C to 50°C, 5% to 99% humidity. Outside it, the page tells you rather than pretending.
  3. Shade and ventilation. A wet bulb in direct sun reads higher, which is the natural wet bulb that goes into WBGT.

For the derivation and the physical picture, see what wet bulb temperature is and why 35°C matters. For how all three thermometers relate, see dry bulb, wet bulb and globe.